Better NDT at Lower Cost

When manufacturers use Magnaflux Quasar, customer problems resulting in quality spills, quarantine, and containment are eliminated.

The chart below represents one customer's experience in implementing Quasar Process Compensated Resonant Inspection.

Magnaflux Quasar Reduces Defects Shipped

MC_Leakers.jpg

The table below documents the NDT performance improvement for different Magnaflux Quasar installations, including the one above. It shows how the number of defective parts shipped was reduced with the introduction of Quasar testing in three different facilities.

Magnaflux Quasar Failure Rate Reduction

Part Process Failure Rate
before Quasar
Failure Rate
after Quasar
Improvement
Master Cylinder Cast 9 ppm 0.7 ppm 13X
Oxygen Sensor Ceramic 80 ppm 2 ppm 40X
Control Arm
Cast 5.5 % 0.25 % 22X

The table below shows the cost savings reported by 3 particular manufacturers after Quasar testing was implemented.

Magnaflux Quasar NDT Cost Reduction

Part
Process NDT Cost
before Quasar

NDT Cost
after Quasar
Savings
per Part
Annual Savings
Ferrous Casting 
Cast
$0.25 $0.03 $0.22 $5.9 M
Knuckle
Cast
$0.80 $0.07 $0.73 $1.3 M
Bearing Cap
Powder Metal
$0.17 $0.03 $0.14 $0.4 M

The "hard" costs in the table above are the hard costs displaced  by using the Magnaflux Quasar method. These manufacturers also benefit from displaced "soft" costs, such as loss of customer confidence, that can easily amount to many multiples of those calculated above.